trane co2 sensor wiring

Q:MASTERCONTROLSU5co CanFab

Install CO2 sensor in conditioned space or return air duct according to instructions packaged with the sensor. Make field wiring connections to LTB installed above per CO2 and Ventilation Override wiring diagram. Route low voltage external field wiring along with and secure to existing low voltage zone sensor or thermostat wiring.

Get Price

Chat With WhatsApp

ReliaTel Microprocessor Controls

CO2 Sensor 010VDC input Remote Minimum Potentiometer (RMP) The Power Exhaust relay is connected to the ECA module as well. See outline on page 12 COMM3/4 Communication Interface Allows ICS communication between a ReliaTel unit and Trane ICS systems as follows: Tracer 100 series Tracer Summit Tracker ComforTrac VariTrac 1 (Comfort Manager) VariTrac 2 (Central Control Panel) …

Get Price

Chat With WhatsApp

Installation Operation Maintenance

mote), power exhaust setpoint, CO2 setpoint, CO2, and ambient dry bulb/ enthalpy sensor or comparative humidity (return air humidity against ambient humidity) sensors, if selected, to control dampers to an accuracy of +/ 5% of stroke. The actuator is spring returned to the closed position any time that power is lost to the unit. It is ca

Get Price

Chat With WhatsApp

Installation Operation Maintenance Trane

power exhaust setpoint, CO2 setpoint, CO2, and ambient dry bulb/enthalpy sensor or comparative humidity (return air humidity against ambient humidity) sensors, if selected, to control dampers to an accuracy of +/ 5% of stroke. The actuator is spring returned to the closed position any time that power is lost to the unit. It is capable of ...

Get Price

Chat With WhatsApp

Sensors Co2

Trane Co2 Sensor wiring, for Trane Air 7. Buy It Now. Free Shipping. Condition: New. Location: New Port Richey,FL,USA. Trane co2 sensor and module I Have 8! OBO 60. Buy It Now. 0 Shipping. Condition: New. Location: Peoria,AZ,USA. AirSense Professional 350 WVRL CO2 Sensor BAS Schneider Tac Life Safety 100. Buy It Now. 0 Shipping. Condition: Used. Location: …

Get Price

Chat With WhatsApp

Mechanical Specifications Trane

Trane Submittal Field Wiring Variable Air Volume Changeover/Bypass Units (CO 2) DemandControlled Ventilation Wall and Duct Sensors (42 Thinner section for cutout 20/2 mm) in. (80 . Sensor uV OUT CONTROLLER COMMON Supply Output jumper Power terminals Ground terminal Output terminals CO Sensor CONTROLLER Signal SHAREO COMMON 24V OUT . Title: CO2 Sensor Author: Trane Salesman Subject: Trane ...

Get Price

Chat With WhatsApp

User guide Trane

Recommended wire size (mm²) Maximum wire length (m) Zone sensor 45 76 115 185 2 300 Electromechanical Thermostat 24V AC Conductors 000 140 141 220 Table 2 Wire sizes and maximum wire lengths

Get Price

Chat With WhatsApp

CO DemandControlled Ventilation DuctSensor

Figure 4: CO2 sensor mounting diameter Figure 5: CO2 sensor insertion depth Wiring the sensor 1. Connect the common wire from the controller to the ground terminal (terminal 0) (Figure 6). 2. For voltage output, connect the signal wire to terminal V. 3. For current output, connect the signal wire to terminal mA. Select the type of output from the

Get Price

Chat With WhatsApp

Installer''s CO2KIN2 Guide

Install CO2 sensor in conditioned space or return airduct according to instructions packed with the sensor. Make field wiring connections to LTB installed above perCO and Ventilation Override wiring 2 See Figure 1diagram. Route low voltage external field wiring along with andsecure to existing low voltage zone sensor or thermostatwiring.

Get Price

Chat With WhatsApp

Product Data Sheet Trane

Wiring Schematic Operating temperature From 32°F to 122°F (0°C to 50°C) Storage temperature From 40°F to 158°F (40°C to 70°C) Humidity range 0–85% relative humidity (RH) Airflow range 0–33 ft/s (0–10 m/s) Output signals • OUT1 (V): 0–10 VDC • OUT2 (I): 4–20 mA or 2–10 VDC (jumper controlled) Note: Sensor is capable of both simultaneously Resolution of analog outputs ...

Get Price

Chat With WhatsApp

Professional gas sensing solution supplier with over 30-year gas sensor manufacturing experience Contact Us