Dwyer CO / NO2 Gas Transmitters. MORE. GWN Series. Veris CO sensors. MORE. GWNP Series. Modular Gas Sensors and Protocol Communication. MORE. KCO Series. Kele Carbon Monoxide Sensor. MORE. KCOC Series. Kele CO Sensor with CO2, RH, or VOC. MORE. KCONO2 Series. CO and NO2 Sensor. MORE. KCOP Series. Kele Carbon Monoxide Detectors. MORE. Q8 Series. ACI …
The official Dwyer Instruments, Inc. site to investigate, learn, and buy online pressure, flow, level, and temperature, gas sensing, and air velocity instrumentations and controls. Dwyer® Dwyer Instruments Limited +44 (0) 1494 461707 sales Cart ; Login or Register ...
Im ersten Versuch werden wir die Messwerte des CO2Sensors lediglich im Seriellen Monitor anzeigen und auswerten. Erst in einem zweiten Schritt wird die Visualisierung durch eine Ampel ergänzt. Sketch // Funduino CO2Messung mit dem Sensor MHZ19B, Messwerterfassung durch Auslesen des PWMSignals int SensorPin = 5; // Der PWMPin des Sensors wird an Pin5 des Mikrocontrollers ...
Sensors. Sensors are for temperature measurement. The different types of Temperature Sensors are RTD, thermocouple, and thermistor models. From probes to thermowells to wireless, these products deal with sensing temperature levels. Series RTD. High Temperature, Mineral Insulated, 304 SS Sheath. Resistance Temperature Detector offers excellent ...
Level Sensors; Carbon Dioxide (CO2) Sensors; Carbon Monoxide (CO) Sensors; Nitrogen Dioxide (NO2) Sensors; Toxic and Combustible Sensors; Volitale Organic Compound (VOC) Transmitters; Condensation Sensors; Occupancy and Vacancy Sensors; Particulate Transmitters; Rain and Snow Sensors; Sensor Accessories and Replacements; Temperature. Averaging ...
The sensor recommended would be the best option we have for sensing temperature and relative humidity for your application. We do not have any options with a remote display that could stretch as far as you are asking, nor are there any on the market to my knowledge. In every case, you would need to utilize a process output, in this case 420 mA, to transmit the readings to a remote display(s ...
Dwyer Carbon Monoxide Sensor,Dwyer Carbon Monoxide Transmitter,Dwyer CO Sensor,Dwyer CO Transmitter,CO Sensor Dwyer, Dwyer CMT200, CMT200 Dwyer, CMT200 Carbon ...
Sensors ; Carbon Monoxide (CO) Sensors ; Dwyer CMTWN ; Dwyer CMTWN. SKU: CMTWN . LIST PRICE: . Quantity discounts available . Quantity Price (0) No Reviews yet. This item is IN Factory STOCK. Quantity + Add to Shopping Cart . Ships in 1 to 2 Days . Details . Dwyer CMTWN : Wall Mount CO Sensor, 0125ppm Meaurement, 420 mA and 210 VDC Outputs . Data …
GSTACLCD | Dwyer Instruments | Gas Specialty Sensors Field Selectable Analog Outputs, CO, Carbon Monixide Detector, Wall Mount with Integral LCD Manufacturer: Dwyer Instruments MPN: GSTACLCD SKU: GSTACLCD. List Price: Today''s Price: (login for better pricing) Availability: 1 In Stock . Available Inventory These numbers are estimates and subject to change …
Sensors ; Carbon Monoxide (CO) Sensors ; Dwyer GSTCCLCD ; Dwyer GSTCCLCD. SKU: GSTCCLCD . LIST PRICE: 1, 1, . Quantity discounts available . Quantity Price (0) No Reviews yet. This item is IN Factory STOCK. Quantity + Add to Shopping Cart . Ships in 1 to 2 Days . Details . Dwyer GSTCCLCD : Wall Mount Carbon Monoxide Sensor, 200 or 500 ppm, 2% …
0 to 2000 PPM CO2: Operating Temperature: 32 to 122°F (0 to 50°C) Output: 0 to 10 VDC for CO2; 20K Ohm NTC Thermistor for temperature: Power Requirements: 18 30 VAC, 18 to 42 VDC : Sensor: NonDispersive Infrared Sensor: Agency Approval: CE
Sensor: Field replaceable electrochemical, 4 years typical lifespan. Range: CO: 0 to 500 PPM, NO2: 10 PPM. Output Drift: 5% per year in air. Coverage Area: 5000 to 7500 sq ft typical. Accuracy: CO: 2% FS, NO2: 3% FS, at the time of calibration. Resolution: CO: 1 PPM; NO2: PPM. Temperature Limits:4 to 122°F (20 to 50°C). Storage Temperature:
Sensors ; Carbon Monoxide (CO) Sensors ; Dwyer GSTAC ; Dwyer GSTAC. SKU: GSTAC . LIST PRICE: . Quantity discounts available . Quantity Price (0) No Reviews yet. This item is IN Factory STOCK. Quantity + Add to Shopping Cart . Ships in 1 to 2 Days . Details . Dwyer GSTAC : Wall Mount Carbon Monoxide Sensor, 200 or 500 ppm, 2% Accuracy, 4 to 20 mA / 0 to 5 …
Dwyer® Home; Products. List by Product Model ... NDIR CO2 Sensor, Universal CO2/RH Outputs, Optional Relay Carbon Dioxide/RH/Temperature Transmitter reduce the number of sensors mounted on a wall or in a duct. Display can be configured to show only temperature or relative humidity or CO2. View More . Series CDX Measures up to 2000 ppm, Adjustable Output Wall Mount Carbon Dioxide …
llll COMelder Test bzw. Vergleich 2021 von COMPUTER BILD: Jetzt die besten Produkte von TOPMarken im Test oder Vergleich entdecken!
Dwyer CO / NO2 Gas Transmitters. The GSTA and GSTC Series Carbon Monoxide/Nitrogen Dioxide Transmitters monitor the gas concentration in underground parking garages and loading docks. Carbon monoxide is commonly used to measure the exhaust of gasoline engines, while nitrogen dioxide is used for diesel engines.
Raumluftqualität / CO2Sensoren; Durchfluss; Solarmessung; Schallpegel; Leckageortung; Messdatenerfassung; Multifunktionen; Zubehör und Kleinteile; KalibrierService. Zur Qualitätssicherung für unsere Kunden bieten wir Kalibrierungen für Druck, Luftgeschwindigkeit, Volumenstrom, Feuchte und Temperatur, sowie CO, CO2 und Schallpegel an. Unsere Kalibrierungen sind auf nationale Normale …
COSensoren von smartGAS sind hier erste Wahl, denn sie zeichnen sich durch eine hervorragende Selektivität sowie eine geringe Drift aus und haben sehr kurze Ansprechzeiten. Anwendungsbereich Emissionsmessung. COSensoren für die Prozesskontrolle in der KunststoffIndustrie In der KunststoffIndustrie spielt Kohlenmonoxid ebenfalls eine große Rolle. Hier wird es in Verbindung mit ...
NDIR CO2 sensor, universal CO2/RH outputs, replaceable humidity / temperature sensors. Starting at Dwyer HP Hand Pump Source of pneumatic pressure and vacuum for verifying the calibration pressure instrumentation. Dwyer TSW Temperature Switch Weatherproof, single or dual stage electronic temperature control with NEMA 4X housing. Starting at Dwyer 641B Air Velocity ...